Posted by ramya, 03-15-2012, 12:49 PM
I see following message in /var/log/messages and my node load has gone high kernel: 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0009): Drive timeout detected:port=0 What can be done to fix this issue ? Why is this error showing up ?

Posted by WebHostDog, 03-15-2012, 02:56 PM
This mean hard drive on port 0 went bad. You need to replace it and rebuild the raid array.

Posted by ramya, 03-16-2012, 11:02 AM
I also see below message kernel: "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message.

Posted by SiteServing, 03-16-2012, 12:03 PM
You better change the hard drive before it is too late. Especially if this is only Raid-1 configuration. Normally 3ware will start rebuilding the raid array automatically if you have not changed anything.

Posted by ramya, 03-16-2012, 01:40 PM
how to find in server which drive is bad ? it had raid 1

Posted by ramya, 03-16-2012, 02:01 PM
How to find which is port 0 and port 1 ?

Posted by PCS-Chris, 03-16-2012, 03:46 PM
Hopefully when you built the server / the person you bought it from labelled the drives. Drive timeout means either the drive has failed, or you used a desktop-grade drive which can timeout on raid cards.